Clearance Sheet R2021-008831

 Department IssuesSigned OffIntl

R320.1.1

All new single-family houses, duplexes, triplexes, condominiums and townhouses shall provide at least one bathroom, located with maximum possible privacy, where bathrooms are provided on habitable grade levels, with a door that has a 29-inch (737 mm) clear opening. However, if only a toilet room is provided at grade level, such toilet rooms shall have a clear opening of not less than 29 inches (737 mm).

 

BOTH BATHS ONLY HAVE A 2'6"; 8'0" DOOR ON FIRST FLOOR

 

R314.3Location.

Smoke alarms shall be installed in the following locations:

  1. 1.In each sleeping room.

  2. 2.Outside each separate sleeping area in the immediate vicinity of the bedrooms.

  3. 3.On each additional story of the dwelling, including basements and habitable attics and not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.

  4. 4.Smoke alarms shall be installed not less than 3 feet (914 mm) horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm required by Section R314.3.

 

PLEASE ADD SMOKE ALARMS IN ALL SLEEPING AREAS

 

R315.1Carbon monoxide protection.

Every separate building or an addition to an existing building for which a permit for new construction is issued and having a fossil-fuel-burning heater or appliance, a fireplace, an attached garage, or other feature, fixture, or element that emits carbon monoxide as byproduct of combustion shall have an operational carbon monoxide alarm installed within 10 feet of each room used for sleeping purposes.

 

PLEASE ADD CARBON DIOXIDE DETECTORS TO PLANS AS CODE PRESCRIBES