SJC Home
Clearance Sheet R1999-002394*004

 Department IssuesSigned OffIntl

Construction Affidavit for Renovation and Remodeling Document (FBC-107.2.1): Please provide a thorough breakdown of the work to be done ( including: sketch or floor plan showing where the new construction is located within the structure; the before and after of reconfigured space; any moved, removed and relocated walls, fixtures, etc.) Information on construction documents shall be dimensioned and drawn upon suitable material and shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations, as determined by the building official. (Note: This is not a $75,000 renovation with the only plans pertaining to converting a garage to office space, please provide better information)

 

Your submittal is clearly misleading of the actual work that was done. The removal of two structural post between a bank of independent windows and installing a roughly ten plus feet sliding glass door without structural engineering isn't quite the same as "replacing sliding glass doors". Clearly you have moved wall, reconfigured spaces, covered up work, remodeling 4 bathrooms & large kitchen, added both a bathroom and converted garage space, and more all without engineering, permits, plans and inspections.

 

REMOVE ALL DRYWALL COVERING THE REVISED, RECONFIGURED AND/OR AREAS REQUIRED FOR ALL ROUGH INSPECTIONS. (Including around the new doors).

 

INSPECTIONS

R110.1 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. It shall be the duty of the permit applicant to cause the work to remain accessible and exposed for inspection purposes…. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection.

 

PLEASE PROVIDE ENGINEERING FOR THIS PROJECT:  Provide structural engineering plans for newly created, modified door & window openings and removed load bearing walls (in master bedroom area). Please have Engineer of Record (Florida Design Professional) sign and/or seal Structural Engineering Drawings (Per FBC-R 301.1.3)

4/19/21 -Engineered Plans as submitted do not match actual construction in several areas, (PLEASE SEE CIRCLED AREAS ON JOB COPY OF PLANS SUBMITTED).

Please provide structural details where load bearing wall modified expanding master bedroom.

Please provide structural detail for living room wall at/above sliding glass door that replaced three independent windows with double 2x8 framing that extended to the second story raised window header, (sufficient lateral support could be missing in the area between the top of the sliding glass door and windows above).

 

PLEASE PROVIDE REQUIRED ENERGY SHEET FOR GARAGE TO OFFICE CONVERSION (per FBC-Energy R101.5)

 

Missing Florida Product Approval: (As required by Florida Statute 553.842 and Florida Administrative Code 9B72)
Please provide Florida Product Approval Sheets to show product approval numbers for exterior components and cladding,(i.e. doors, windows, siding, soffit, roofing material). Specific products are identified by the decimal places

 

JOB COST/BUILDING PERMIT VALUATION: The applicant for a permit shall provide and estimated permit value at time of application. Permit valuations shall include total value of work, including materials and labor for which the permit is being issued, such as electrical, gas, mechanical, plumbing equipment and permanent systems. If, in the opinion of the building official, the valuation is underestimated on the application, the permit shall be denied and the final building permit valuation shall be set by the building official.

(Please submit an Executed Contract documenting the dollar valuation of the work. The submitted valuation seems low/questionable.) per FBC-R109.3

 

Clearance Sheet/Site Plan Approval Required: Please submit Site Plan for approval from the Clearance Dept. for approval of the garage to office conversion.

 

DUE TO MISSING INFORMATION: Review cannot be completed at this time. Additional items may be required depending on new information provided.

 

4/19/21  AS PER ORDINANCE # 98-42 An additional fee due and payable at permitting shall be of $100 each for any second resubmission of plans. Per FL. Statute 553.80(2)(b), on any third and subsequent resubmissions that do not correct a code violation that is specifically and continuously noted in each previous rejection, a fee of four times the amount of the fee attributed to plan review will be charged.