Plan reviewed to replace all exterior doors (including rated doors), demo and replace tile shows and tub surrounds, replace shorer fixtures and faucets, replace carpet and pad and paint all units in an existing building. Reviewed using FFPC 6th edition effective Dec. 31, 2017.
Reviewer: V.Vitori 904 209 1748
To schedule fire inspections please call 827-6842 (automated system). Questions about inspections please call 209-1740x1. Review by the AHJ shall not relieve the applicant of the responsibility for compliance with the Code.
|
3/18/2020
| VVitori |
|
|
Original plans (permit 19800182 -20 min) shows several fire rated doors with self closers. While there are several rated doors in the building, the only fire rated doors showning work in this submittal is for the front door and jambs. These doors shall meet all requirements for fire doors (including self closing or automatic closing). 101:12.4.6.3
|
3/18/2020
| VVitori |
|
|
At the time of fire final be prepared to provide a copy of the manufacturer specification sheets to the fire inspector showing that the interior finish will meet:
- floor finish shall meet either: a) ASTM D 2859 for carpet and carpet like materials or b) has a minimum critical radiant flux of .1 W/cm2 for non carpet flooring. 101:30.3.3.3.
If there are multiple finishes, label each spec sheet identifying each product, its location AND highlight the area showing illustrating it meets the applicable Code requirement.
|
3/18/2020
| VVitori |
|
|
INFORMATIONAL ONLY NO RESPONSE NECESSARY: Make sure existing safety features are replaced and/or functional. Included but not limited to:
- smoke detectors NFPA 101 30/31.3.4.5 - tagged (within the last year) fire extinguishers at appropriate locations NFPA 1 13.6. - address or unit numbers in place NFPA 1 10.12.1 - all electrical covered NFPA 1 11.1 - exterior rated doors self close NPFA 101 30/31.3.6
|
3/18/2020
| VVitori |