Clearance Sheet M2021-006764

 Department IssuesSigned OffIntl

Plans for a 45 head Wet sprinkler system submitted as a NFPA 13R for a triplex.  This is for the aboveground only.  The attic piping will be insulated to provide the freeze protection.  FDC provided.  The sprinkler riser is located inside of an insulated garage wall with exterior and interior access panels.  Per the contractor the riser will be maintained at 40 degrees in this configuration.


                                                        
Reviewed using FFPC 7th edition effective Dec. 31, 2020.
Reviewer: PJ Webb 904 209 1744 pwebb@sjcfl.us
 
To schedule fire inspections please call 827-6842 (automated system). Questions about inspections please call 209-1740x1.
Review by the AHJ shall not relieve the applicant of the responsibility for compliance with the Code.
 
For questions regarding comments you may reach me at either: 904 209 1744 or pwebb@sjcfl.us.
To schedule fire i

3/8/2022 PWebb