| | Department Issues | Signed Off | Intl |
|
|
1) This was a preliminary review of the Classic Car Storage Bldg
|
1/11/2019
| jadams |
|
|
2) Plans are incomplete to do a complete review need structural engineering for building and foundation
|
1/11/2019
| jadams |
|
|
3) Code Summary need to address occupancy as mixed use S-1 and Assembly based on the fire wall separation it would be separated occupancy . FBC 508 .
|
1/11/2019
| jadams |
|
|
4) Section 406.8 2017 Florida building code storage and repair garages shall be constructed in accordance with the Florida Fire Prevention Code.
|
1/11/2019
| jadams |
|
|
|
5) Please provide a Florida product approval list including identifying the glazing assemblies for the 1-hour separation. |
|
1/11/2019
| jadams |
|
|
6) Garage floor shall comply with section 406.3.3 FBC if floor drains are used in automobile storage area an oil separator is required
|
1/11/2019
| jadams |
|
|
7) Electrical plans need to address and comply with section 405 of the 2017 FBC energy conservation code
|
1/11/2019
| jadams |