42208525-403
| MC FNL |
12/16/2022
|
12/19/2022
| A |
-
|
|
22205036-204
| EL FNL |
12/16/2022
|
12/19/2022
| A |
-
|
|
12202784-125
| BL FNL |
12/16/2022
|
12/19/2022
| A |
-
|
|
42210587-408
| GASFNL |
12/14/2022
|
12/14/2022
| A |
-
|
|
42209397-408
| GASFNL |
12/14/2022
|
12/14/2022
| A |
-
|
|
42208525-403
| MC FNL |
12/14/2022
|
12/14/2022
| D |
-
|
|
32202192-304
| PL FNL |
12/14/2022
|
12/14/2022
| A |
-
|
|
22205036-204
| EL FNL |
12/14/2022
|
12/14/2022
| D |
-
|
|
12202784-125
| BL FNL |
12/14/2022
|
12/14/2022
| D |
-153 Beachside Dr
1. Outlet for water heater needs to be GFCI protected.
2. All exterior receptacles need to be GFCI protected.
3. All garage receptacles need to be GFCI protected.
4. Provide arc shield at fryer outlet.
5. Provide receptacles within 2’ of edge of counter in kitchen.
6. Plug at
|
|
22205036-213
| MTR CN |
11/9/2022
|
11/9/2022
| A |
-
|
|
42210587-407
| GS RGH |
7/29/2022
|
7/29/2022
| A |
-
|
|
12202784-109
| INSULA |
7/29/2022
|
7/29/2022
| A |
-
|
|
12202784-106
| RF D&T |
7/15/2022
|
7/15/2022
| A |
-
|
|
42209397-407
| GS RGH |
7/15/2022
|
7/15/2022
| A |
-
|
|
42208525-401
| MC RGH |
7/15/2022
|
7/15/2022
| A |
-
|
|
32202192-303
| RGH PL |
7/15/2022
|
7/15/2022
| A |
-
|
|
22205036-203
| RGH EL |
7/15/2022
|
7/15/2022
| A |
-
|
|
12202784-105
| FRAMNG |
7/15/2022
|
7/15/2022
| A |
-
|
|
12202784-100
| CM RGH |
7/15/2022
|
7/15/2022
| A |
-
|
|
42209397-407
| GS RGH |
7/13/2022
|
7/13/2022
| D |
-Provide minimum 3psi.
|
|
42208525-401
| MC RGH |
7/13/2022
|
7/13/2022
| D |
-
|
|
32202192-303
| RGH PL |
7/13/2022
|
7/13/2022
| D |
-
|
|
22205036-203
| RGH EL |
7/13/2022
|
7/13/2022
| D |
-
|
|
12202784-105
| FRAMNG |
7/13/2022
|
7/13/2022
| D |
-
|
|
12202784-100
| CM RGH |
7/13/2022
|
7/13/2022
| D |
-Missing outlets for wall space. Recheck nail plates. Strap within 12”at panel. Hook up exhaust duct to fan housing.
|
|
12202784-106
| RF D&T |
7/13/2022
|
7/13/2022
| D |
-Over ent straps(hts24). Missing cs18 multiple locations.
|
|
12202784-106
| RF D&T |
7/11/2022
|
7/11/2022
| D |
-see notes on plans
|
|
12202784-131
| WINDOW |
7/6/2022
|
7/6/2022
| A |
-
|
|
12202784-106
| RF D&T |
7/6/2022
|
7/6/2022
| C |
-
|
|
12202784-130
| P R TI |
6/9/2022
|
6/9/2022
| A |
-
|
|
12202784-116
| RF SHT |
6/9/2022
|
6/9/2022
| A |
-
|
|
12202784-107
| SHTHNG |
6/9/2022
|
6/9/2022
| A |
-
|
|
12202784-130
| P R TI |
6/8/2022
|
6/8/2022
| D |
-Finish building garage wall to pass this inspection.
|
|
12202784-116
| RF SHT |
6/8/2022
|
6/8/2022
| D |
-Multiple loose roof at first floor. Inspection stopped. Recheck 2nd floor before next inspection.
|
|
12202784-107
| SHTHNG |
6/8/2022
|
6/8/2022
| D |
-Missing nails and provide 1/8” gaps. Marked orange. Finish building garage wall.
|
|
22205036-205
| TMP PL |
6/8/2022
|
6/8/2022
| A |
-
|
|
12202784-102
| SLAB.. |
5/4/2022
|
5/4/2022
| A |
-
|
|
32202192-301
| U/SLAB |
4/11/2022
|
4/12/2022
| A |
-
|
|
12202784-101
| FND/FT |
3/10/2022
|
3/10/2022
| A |
-Pad footings not installed around perimeter. check at slab height. Rear porch post pad footings installed at time of inspection.
|