12118176-125
| BL FNL |
12/7/2023
|
12/7/2023
| A |
-
|
|
12118176-125
| BL FNL |
12/1/2023
|
12/1/2023
| D |
-still missing stairs and guard rail
|
|
12118176-111
| P FNDT |
11/7/2023
|
11/7/2023
| A |
-for garage stairs
|
|
82303347-805
| IRRGTN |
10/26/2023
|
10/26/2023
| A |
-
|
|
42213491-403
| MC FNL |
10/26/2023
|
10/26/2023
| A |
MINI, CHARLIE R-
|
|
32202947-304
| PL FNL |
10/26/2023
|
10/26/2023
| A |
-
|
|
22111827-204
| EL FNL |
10/26/2023
|
10/26/2023
| A |
-notes
|
|
12118176-125
| BL FNL |
10/26/2023
|
10/26/2023
| D |
-seal hole in AC closet, missing blown insulation cert, missing termite treat cert, missing blower door test cert, steps and guard rail missing in garage, seal hood range vent at ceiling, weather stripping at exterior doors, label breakers on exterior panel, master toilet not installed
|
|
22111827-213
| MTR CN |
8/8/2023
|
8/8/2023
| A |
-
|
|
22111827-213
| MTR CN |
7/10/2023
|
7/10/2023
| D |
-conductors loose under lugs, need to torque correctly, and unused openings need to be closed at dead front, inside of house safed off
|
|
12118176-108
| LTH NL |
5/25/2023
|
5/24/2023
| A |
-
|
|
12118176-108
| LTH NL |
5/23/2023
|
5/23/2023
| D |
-Not complete
|
|
12118176-109
| INSULA |
1/25/2023
|
1/25/2023
| A |
-
|
|
12118176-105
| FRAMNG |
1/4/2023
|
1/4/2023
| A |
-
|
|
12118176-100
| CM RGH |
1/4/2023
|
1/4/2023
| A |
-
|
|
42213491-401
| MC RGH |
12/22/2022
|
12/22/2022
| A |
LAMM, JEFFREY CLELAND-
|
|
32202947-303
| RGH PL |
12/22/2022
|
12/22/2022
| A |
-
|
|
22111827-203
| RGH EL |
12/22/2022
|
12/22/2022
| A |
-
|
|
12118176-105
| FRAMNG |
12/22/2022
|
12/22/2022
| D |
-A9-A10 2-ply fasteners not complete per truss details. Please check all 2-ply's.
Both A11 4-ply girders require screws and fasteners per truss details.
|
|
12118176-100
| CM RGH |
12/22/2022
|
12/22/2022
| D |
-See notes. Insulation will cover fastener's do not insulate. thank you
|
|
32202947-302
| TOPOUT |
12/14/2022
|
12/14/2022
| A |
-
|
|
42213491-401
| MC RGH |
12/9/2022
|
12/9/2022
| D |
MARVEL, ROBERT E-
|
|
32202947-303
| RGH PL |
12/9/2022
|
12/9/2022
| D |
-
|
|
22111827-203
| RGH EL |
12/9/2022
|
12/9/2022
| D |
-
|
|
12118176-105
| FRAMNG |
12/9/2022
|
12/9/2022
| D |
-
|
|
12118176-100
| CM RGH |
12/9/2022
|
12/9/2022
| D |
-Pleasant colony
1. Fire foam/blocking missing multiple locations.
2. Steam NM cable within 12” of electric panel. Electrical is not finished. Cables hanging out of boxes.
3. Nail plates missing. Multiple locations. Electrical and plumbing.
4. Top out has not been done.
5. Build structural supp
|
|
12118176-131
| WINDOW |
12/5/2022
|
12/5/2022
| A |
-
|
|
12118176-131
| WINDOW |
10/26/2022
|
10/26/2022
| D |
-Windows not complete. Missing window openings need to be sealed to protect interior. Windows with frame in-between need to be taped/sealed.
|
|
12118176-116
| RF SHT |
7/28/2022
|
7/28/2022
| A |
-
|
|
12118176-106
| RF D&T |
7/28/2022
|
7/28/2022
| A |
-HST12 from beam to post on back porch. check on 100
|
|
12118176-106
| RF D&T |
7/14/2022
|
7/14/2022
| C |
-need roof to pass first
|
|
12118176-130
| P R TI |
7/14/2022
|
7/14/2022
| A |
-
|
|
12118176-116
| RF SHT |
7/14/2022
|
7/14/2022
| D |
-loose roof front right corner and second floor above garage
|
|
12118176-130
| P R TI |
7/1/2022
|
7/1/2022
| D |
-missing straps at front porch columns (second columns) LSTA in back
|
|
12118176-116
| RF SHT |
7/1/2022
|
7/1/2022
| D |
-multiple loose locations. punch house
|
|
12118176-107
| SHTHNG |
7/1/2022
|
7/1/2022
| A |
-
|
|
12118176-102
| SLAB.. |
5/23/2022
|
5/23/2022
| A |
-
|
|
12118176-111
| P FNDT |
5/12/2022
|
5/12/2022
| A |
-
|
|
32202947-301
| U/SLAB |
5/12/2022
|
5/12/2022
| A |
-
|
|
12118176-111
| P FNDT |
2/23/2022
|
2/23/2022
| A |
-
|
|
12118176-101
| FND/FT |
1/10/2022
|
1/10/2022
| A |
-
|
|
22111827-205
| TMP PL |
12/15/2021
|
12/15/2021
| A |
-
|