Permit # 32202947
KUSHNER, RICHARD G
Permit #AprvDescSchedDtInspDtResultRemarks
12118176-125 BL FNL 12/7/2023 12/7/2023 A -
12118176-125 BL FNL 12/1/2023 12/1/2023 D -still missing stairs and guard rail
12118176-111 P FNDT 11/7/2023 11/7/2023 A -for garage stairs
82303347-805 IRRGTN 10/26/2023 10/26/2023 A -
42213491-403 MC FNL 10/26/2023 10/26/2023 A -
32202947-304 PL FNL 10/26/2023 10/26/2023 A MINI, CHARLIE R-
22111827-204 EL FNL 10/26/2023 10/26/2023 A -notes
12118176-125 BL FNL 10/26/2023 10/26/2023 D -seal hole in AC closet, missing blown insulation cert, missing termite treat cert, missing blower door test cert, steps and guard rail missing in garage, seal hood range vent at ceiling, weather stripping at exterior doors, label breakers on exterior panel, master toilet not installed
22111827-213 MTR CN 8/8/2023 8/8/2023 A -
22111827-213 MTR CN 7/10/2023 7/10/2023 D -conductors loose under lugs, need to torque correctly, and unused openings need to be closed at dead front, inside of house safed off
12118176-108 LTH NL 5/25/2023 5/24/2023 A -
12118176-108 LTH NL 5/23/2023 5/23/2023 D -Not complete
12118176-109 INSULA 1/25/2023 1/25/2023 A -
12118176-105 FRAMNG 1/4/2023 1/4/2023 A -
12118176-100 CM RGH 1/4/2023 1/4/2023 A -
42213491-401 MC RGH 12/22/2022 12/22/2022 A -
32202947-303 RGH PL 12/22/2022 12/22/2022 A LAMM, JEFFREY CLELAND-
22111827-203 RGH EL 12/22/2022 12/22/2022 A -
12118176-105 FRAMNG 12/22/2022 12/22/2022 D -A9-A10 2-ply fasteners not complete per truss details. Please check all 2-ply's. Both A11 4-ply girders require screws and fasteners per truss details.
12118176-100 CM RGH 12/22/2022 12/22/2022 D -See notes. Insulation will cover fastener's do not insulate. thank you
32202947-302 TOPOUT 12/14/2022 12/14/2022 A LAMM, JEFFREY CLELAND-
42213491-401 MC RGH 12/9/2022 12/9/2022 D -
32202947-303 RGH PL 12/9/2022 12/9/2022 D MARVEL, ROBERT E-
22111827-203 RGH EL 12/9/2022 12/9/2022 D -
12118176-105 FRAMNG 12/9/2022 12/9/2022 D -
12118176-100 CM RGH 12/9/2022 12/9/2022 D -Pleasant colony 1. Fire foam/blocking missing multiple locations. 2. Steam NM cable within 12” of electric panel. Electrical is not finished. Cables hanging out of boxes. 3. Nail plates missing. Multiple locations. Electrical and plumbing. 4. Top out has not been done. 5. Build structural supp
12118176-131 WINDOW 12/5/2022 12/5/2022 A -
12118176-131 WINDOW 10/26/2022 10/26/2022 D -Windows not complete. Missing window openings need to be sealed to protect interior. Windows with frame in-between need to be taped/sealed.
12118176-116 RF SHT 7/28/2022 7/28/2022 A -
12118176-106 RF D&T 7/28/2022 7/28/2022 A -HST12 from beam to post on back porch. check on 100
12118176-106 RF D&T 7/14/2022 7/14/2022 C -need roof to pass first
12118176-130 P R TI 7/14/2022 7/14/2022 A -
12118176-116 RF SHT 7/14/2022 7/14/2022 D -loose roof front right corner and second floor above garage
12118176-130 P R TI 7/1/2022 7/1/2022 D -missing straps at front porch columns (second columns) LSTA in back
12118176-116 RF SHT 7/1/2022 7/1/2022 D -multiple loose locations. punch house
12118176-107 SHTHNG 7/1/2022 7/1/2022 A -
12118176-102 SLAB.. 5/23/2022 5/23/2022 A -
12118176-111 P FNDT 5/12/2022 5/12/2022 A -
32202947-301 U/SLAB 5/12/2022 5/12/2022 A MINI, CHARLIE R-
12118176-111 P FNDT 2/23/2022 2/23/2022 A -
12118176-101 FND/FT 1/10/2022 1/10/2022 A -
22111827-205 TMP PL 12/15/2021 12/15/2021 A -